TEMPERATURE VARIATION: 0,15 °C ( ± 0,27
°F)
REGULATION: Proportional controller, 20 second cycles*
OPERATING MODES: Manual
Automatic with temporary bypass
Cottage Sitter and Freeze Alarm Input**
PROGRAMMING: 4 settings / day
Each day can have different setbacks
Early start function***
Temperature memory****
PROTECTION: Protected memory
No battery required
CONNECTION: Single pole, 2 wires
SIZE: 38 x 127 x 125 mm
1,5 x 5 x 4,9 inches
* : This thermostat is equipped with a micro processor that analyses
the system's past performances in order to optimize future commands.
At the beginning of each cycle, the system sends a command that defines
the portion of time the unit is heating during the next cycle.
** : Allows, through a Cottage Sitter or Freeze Alarm FAD2, switching from
normal operating mode (Manual or Auto) to Vacation mode, or vice-versa.
*** : Function that calculates the optimum time to start the heating
system to achieve the desired temperature setting at the programmed
time.
**** : The user can enter a daytime, night-time and vacation time
temperature. |